Unvented cylinders installed and serviced across Cardiff and South Wales
An unvented cylinder gives you instant, unlimited hot water and frees up airing cupboard space. Cardiff Plumbing Limited installs, services and repairs them to Building Regulations, with pressure relief and all safety checks built in.
- Mains-pressure hot water throughout the house
- Installed to Building Regulations and Water Fittings
- All safety devices and pressure tests included
What an unvented cylinder actually does
A traditional hot-water tank relies on gravity; it sits in the loft and relies on a storage heater or immersion to warm the water. The pressure at the tap is weak, showers are sluggish and you get better flow from the cold tap than the hot.
An unvented cylinder is connected directly to the mains water supply. It heats water on demand or stores it at mains pressure. The hot water flows as hard as the cold, every tap and shower works properly, and you're not at the mercy of a loft tank and a boiler struggling to reheat it.
Signs you'd benefit from oneWhen an unvented cylinder makes the most sense
Weak shower pressure
If your shower trickles when others are running, or struggles to mix hot and cold evenly, the gravity-fed tank can't keep up. Mains pressure fixes this instantly.
An airing cupboard full of pipe and tank
The loft tank and all its pipes take up space. A compact cylinder sits neatly in a corner and frees you to use that cupboard for storage.
Running out of hot water mid-shower
A storage cylinder lets you heat enough water for a bath and showers back-to-back. No more waiting for the boiler to reheat the tank.
Different hot and cold pressure at each tap
When cold comes from the mains and hot from the loft, mixer taps struggle to balance. Unvented supplies both sides at the same pressure, so mixing is smooth.
An old, inefficient boiler struggling to reheat
If your boiler works flat-out all winter just to keep the tank warm, an unvented cylinder with a heat pump or solar panel option can be much more efficient.
Planning a loft conversion or renovation
A cylinder lets you remove the tank from the loft, freeing the space. It's the perfect time to upgrade to mains pressure.
Choosing the right cylinder for your home
Size matters. Too small and you run out mid-bath; too large and you waste energy keeping unused water hot. The right choice depends on your household size, how you heat water and your budget.
- Indirect unvented cylinders
- Heated by a boiler via a coil inside the tank. The boiler does the warming, the cylinder stores the heat. Good if you have a combi boiler as well, or want the option of solar panels feeding into it. Sizes typically 100–300 litres.
- Direct unvented cylinders (electric)
- An immersion heater sits inside the tank. Simplest to install and no boiler needed, but slower to reheat in winter and more expensive to run if you use a lot of hot water. Good for small households or as backup.
- System boiler with unvented cylinder
- A boiler designed to work with an unvented cylinder, often as a package. The boiler circulates hot water through the coil and may also supply radiators. Very efficient and reliable.
- Thermal store (heat battery)
- A large insulated tank that stores heat from your boiler, solar panels or heat pump. Delivers hot water on demand and heats radiators. More expensive upfront but versatile if you're combining heat sources.
What goes inside and why it matters
A good unvented cylinder has a pressure vessel (the tank), a heat source (boiler coil or immersion), thermal insulation, and safety devices. The safety kit is not optional.
- Pressure vessel must be sturdy steel with a sound enamel lining. Cheap vessels develop internal rust and fail early.
- Expansion vessel absorbs the pressure rise as water heats. Without it, the safety valve opens constantly, wasting water and energy.
- Pressure relief valve opens if the system overshoots. It must be sized for the cylinder and regularly tested.
- Temperature and pressure relief valve (TPR) is a second fail-safe. If the thermostat sticks and water overheats, the TPR valve opens and dumps the excess safely.
- Isolation valve lets you shut off the mains water supply to the cylinder for maintenance or repairs.
- Insulation can be foam-wrapped or supplied separately. A thick wrap (100mm+) keeps the heat in and reduces running costs.
- Temperature gauge so you know the water temperature at a glance.
Reputable brands include Baxi, Vaillant, Worcester, Viessmann and Gledhill. These offer good warranty support and parts availability in Cardiff.
Everything in an unvented cylinder installation
- Surveying the existing pipework and boiler to check suitability
- Choosing the right size and type for your home and budget
- Isolating and draining the old system if replacing
- Removing the old cylinder and loft tank if present
- Installing the new cylinder with all pipework in place
- Fitting the pressure relief valve, TPR valve and expansion vessel
- Isolating valves on the mains and heating flow
- Connecting the boiler coil or immersion heater
- Insulating all exposed pipes and the cylinder jacket
- Flushing the system to remove debris and commission the whole installation
- Full pressure test at mains supply and heating flow
- Temperature and flow testing to confirm hot water reaches all outlets
- Showing you how to use and maintain it safely
- Paperwork and Building Regulations sign-off where required
We work with your boiler engineer if needed to ensure the heating side is set up correctly.
From survey to hot water on tap
Visit and survey
We look at your existing system, pipework, boiler and space. We'll talk through cylinder options, sizes and costs, and check if any Building Regulations sign-off is needed.
Order and plan the work
Once you say yes, we order the cylinder and arrange the installation date. If you have a boiler engineer, we coordinate with them so the work runs smoothly.
Install and commission
Water off, old system drained and removed. New cylinder fitted, all pipes connected, safety devices in place, then filled, flushed and tested under pressure.
Handover and training
We show you how to adjust the thermostat, what the safety valves do, and when to book annual maintenance. You're left with a system that's reliable and properly set up.
Fitted to meet Building Regulations and Water Fittings
Unvented cylinders are covered by Building Regulations Part G and the Water Supply (Water Fittings) Regulations 1999. They must be installed by a competent person — that means a plumber with appropriate qualifications or accreditation.
All safety devices (relief valves, TPR valve, expansion vessel) must be WRAS-approved or equivalent. The system is tested at the working pressure to confirm it's sound. If the job is notifiable to Building Control, we arrange the inspection or provide certification from the cylinder manufacturer.
The cold water supply to the cylinder must come from the mains and cannot take water from a storage tank. Hot water delivered to the outlets must be thermostat-controlled and blended to 48°C or lower at the spout (legionella risk above that).
Pricing factors for your cylinder
- Cylinder sizeLarger capacity means more cost, but buying too small forces you to fit a bigger one later.
- TypeA simple electric indirect is cheaper than a system boiler package or thermal store.
- Your existing boilerIf the boiler can work with an unvented system, the cost is lower. If you need a new boiler as well, budget accordingly.
- Pipework changesRerouting pipes for a new location, or installing isolation valves where none exist, adds time and cost.
- Removal of old systemsDraining and removing the loft tank, pipes and old cylinder takes labour.
- Building RegulationsSome jobs need Building Control inspection or certification, which incurs a fee.
- Commissioning timeSystem pressure testing, flushing, thermostat balancing and handover take care; a rushed job saves nothing and risks problems.
Keeping your unvented cylinder safe and efficient
Annual service
Once a year, we test the relief valves, check the expansion vessel pressure and inspect the thermostat. Early faults are caught before they cause problems.
Bleed the system
If you lose pressure or the relief valve weeps, the expansion vessel may have failed. We refill it and test the system to find the cause.
Monitor water quality
If your water is very hard (chalky deposits on taps), the cylinder's heating coil can scale up over time. Softening the water or adding a dosing treatment helps.
Test isolation valves
The mains isolation valve and the heating flow valve should close easily. Turn them a quarter turn every few months so they don't seize.
Know your relief valve
The pressure relief valve may discharge water into the tray or drain during heating. This is normal. If it's constant, the expansion vessel pressure needs checking.
Temperature setting
Keep the thermostat at 60°C. Too low and legionella bacteria can grow in stagnant water; too high and you risk scalding and waste energy.
Often needed alongside unvented cylinder work
Bathroom plumbing
New baths, basins, showers and supplies fitted and plumbed in to work with your unvented system.
Find out more →Shower pump
If you need a booster pump for a loft shower or over a bath, we fit and commission it to work with your cylinder.
Find out more →Pipework repairs
Rerouting pipes for a new cylinder location, or replacing worn pipes when upgrading your water system.
Find out more →Unvented cylinder questions, answered plainly
Can an unvented cylinder work with any boiler?
Not all boilers are designed for unvented cylinders. Combi boilers heat water on demand and don't need a cylinder. If you have a system boiler or standard boiler, it can work with an unvented cylinder via a heating coil. We check your boiler's capability when we visit and advise if an upgrade is needed.
What's the difference between unvented and a combi boiler?
A combi boiler heats water on the spot when you turn the tap on; there's no storage tank. An unvented cylinder stores hot water at mains pressure, so you get instant flow to multiple outlets and don't run out during heavy use. Combis suit smaller homes with modest hot-water demand; unvented cylinders are better for families and homes with multiple bathrooms.
Do I need Building Regulations approval?
In many cases, yes. Installing an unvented cylinder is notifiable to Building Control if you don't already have one, or if you're replacing an old one with a bigger capacity. We arrange the inspection or provide certification from the manufacturer. The cost is usually included in the quote. Some older homes may have exemptions, but we'll confirm before starting.
What happens if the relief valve keeps dripping?
A small drip when the water is heating is normal; the relief valve is doing its job as pressure builds. If it drips constantly or heavily, the expansion vessel pressure may be wrong or the thermostat is set too high. Call us and we'll diagnose it. Never ignore a persistent weep as it wastes water and energy.
Can I use solar panels with an unvented cylinder?
Yes. An indirect unvented cylinder has a heating coil that can be fed by solar panels as well as your boiler. In summer, the panels can do most of the work; in winter, the boiler takes over. It's an efficient setup if you're planning renewable heating.
How often should the cylinder be serviced?
We recommend an annual service. We test the relief valves, check the expansion vessel pressure, inspect the thermostat and look for corrosion or leaks. Regular checks catch problems early and keep the system safe and efficient. If you're on a boiler maintenance plan, we can usually add the cylinder inspection to that visit.
Ready to upgrade to mains-pressure hot water?
A qualified plumber will assess your home, explain your options and give you a clear price. No high-pressure sales, just honest advice.
03300437479